15 research outputs found

    COMPARATIVE ANALYSIS ON MUSCLE STRENGTH AMONG PATIENTS WHO UNDERWENT ARTHROSCOPIC TENOTOMY OF THE LONG HEAD OF THE BICEPS IN RELATION TO ESTHETIC DEFORMITY

    Get PDF
    ABSTRACTObjective: To determine whether there was any discrepancy in elbow flexion strength among patients with and without evident clinical deformity resulting from arthroscopic tenotomy on the long head of the biceps. Method: A group of 120 patients who underwent this procedure were evaluated. After applying the exclusion criteria, 89 patients remained in the analysis. Eighteen months after the operation (median), the elbow flexion strength was measured in newtons using a digital dynamometer. Three consecutive measurements were made and the average was used. The dominant and non-dominant sides were compared. Sex, age and mean elbow flexion strength in the operated and contralateral arms of patients with and without apparent clinical deformity were evaluated. Results: The median elbow flexion strength among the patients with evident clinical deformity was 17.78 N for the dominant arm and 20.87 N for the non-dominant arm. The difference was 2.51 N. In the group without evident clinical deformity, the difference was 2.14 N. The median muscle strength in the operated arm was 17.26 N, while the median was 20.06 N in the non-operated arm, thus suggesting that there was a significant loss of muscle strength (p = 0.005). The difference in muscle strength loss between the patients with and without evident deformity was not considered statistically significant (p = 0.977). Conclusion: The patients who underwent arthroscopic tenotomy on the long head of the biceps with or without apparent clinical deformity from distal migration presented similar elbow flexion muscle strength

    Avaliação da retenção hídrica com a técnica do soro fisiológico em suspensão durante a artroscopia do ombro

    No full text
    OBJETIVO: Avaliar a retenção hídrica após a artroscopia do ombro quando utilizada a técnica de infusão de soro fisiológico em suspensão, com o propósito de identificar os pacientes com risco para ganho hídrico excessivo no transoperatório. MÉTODOS: Foi analisado um grupo de 131 pacientes, após uma única exclusão, que foram submetidos à artroscopia do ombro e tiveram seu índice de massa corporal (IMC) aferido para fins de classificação entre os diferentes graus de obesidade. O posicionamento foi o decúbito lateral com o membro superior em suporte de tração. A distensão articular utilizou o soro fisiológico em suspensão com equipo de quatro vias e quatro frascos de soro fisiológico de 2.000ml colocados na mesma altura, deixando a pressão de infusão variar entre 31 e 97mmHg. Os pacientes foram submetidos à medição do peso tão logo tinham condições de ficar em posição ortostática ao lado da cama na sala de recuperação. As variáveis estudadas foram: peso corporal pré e pós-operatório, IMC, quantidade de soro fisiológico utilizado no sistema de irrigação, quantidade de soro fisiológico infundido endovenoso e o tempo do procedimento cirúrgico. RESULTADOS: O ganho hídrico médio aferido na série de pacientes avaliados foi de 1.901 (± 968) gramas. Foi encontrada correlação moderada entre o soro fisiológico do sistema de irrigação e o ganho hídrico (r = 0,372; r² = 0,138; P < 0,001), bem como para o aporte endovenoso e o ganho hídrico (r = 0,253; r² = 0,064; P = 0,004). Quando os aportes hídricos foram verificados em conjunto, aparece correlação significativa, mas de efeito moderado (r = 0,381; r² = 0,0146; P < 0,001). Foi encontrada correlação de magnitude maior entre o tempo do ato cirúrgico e o ganho hídrico apresentado pelos pacientes (r = 0,586; r² = 0,264; P < 0,001). Ao agrupar os pacientes com IMC abaixo de 30 (normal e sobrepeso) e compará-los com os com IMC acima de 30 (obesidade grau 1, 2 e mórbida), foi verificada a existência de retenção hídrica maior entre os obesos (2.111g ± 1.144g) (mediana de 1.900g) do que nos não obesos (1.851g ± 921g) (mediana: 1.754g) (P = 0,292). CONCLUSÕES: A retenção hídrica encontrada foi de 1.901 (± 968) gramas. Apenas 14,6% do ganho de peso encontrado são decorrentes do aporte hídrico transoperatório. Pacientes submetidos a procedimentos artroscópicos prolongados retêm mais líquido. Pacientes com obesidade graus 1, 2 e mórbida parecem ter mais expressiva tendência para maior ganho de peso transoperatório

    Avaliação da deformidade estética após a tenotomia da cabeça longa do bíceps na artroscopia do ombro Assessment of esthetic deformity after tenotomy of the long head of the biceps in shoulder arthroscopy

    No full text
    OBJETIVO: Analisar a freqüência da queixa estética resultante do procedimento da tenotomia da cabeça longa do bíceps (CLB), com o propósito de criar um critério de análise pré-operatória capaz de identificar os pacientes com tendência a apresentarem queixa estética decorrente de tal procedimento, com a intenção de reduzir sua incidência. MÉTODOS: Foi analisado um grupo de 89 pacientes (90 ombros) submetidos à tenotomia artroscópica da CLB. Os pacientes incluídos no estudo tiveram seu índice de massa corporal (IMC) aferido e foram classificados entre os diferentes graus de obesidade. Foram aferidas a dobra cutânea abdominal e a tricipital contralateral com um adipômetro graduado em milímetros, bem como determinado o biótipo de cada indivíduo através do ângulo mensurado no apêndice xifóide. A tenotomia do CLB, quando indicada, foi realizada junto a sua inserção no labrum superior da glenóide. Os pacientes foram questionados quanto à percepção da deformidade residual gerada pela tenotomia do CLB. As variáveis estudadas foram: idade, sexo, lado operado, dominância, biótipo, grau de obesidade, dobra cutânea abdominal e dobra cutânea tricipital contralateral. Foram avaliados 77 pacientes com média de 15,14 (± 10,7) meses de pós-operatório. RESULTADOS: Não houve queixa da deformidade em 50 (64,9%), enquanto 27 pacientes (35,1%) manifestaram alguma queixa estética. A análise estatística não foi significativa quando avaliou de forma cruzada a idade (p = 0,788), o lado (p = 0,075) e o biótipo (p = 0,529) dos pacientes que apresentaram queixa estética de sua deformidade residual. Houve correlação significativa para a queixa da deformidade quando foram avaliados o sexo (p = 0,004), a dominância (p = 0,026) e ao agrupar os pacientes com IMC abaixo de 30 (normal e sobrepeso) e compará-los com os pacientes com IMC acima de 30 (obesidade graus 1, 2 e mórbida) (p = 0,005). Demonstrou-se correlação significativa para a queixa da deformidade nos pacientes com a dobra cutânea abdominal abaixo de 23,2mm (p = 0,003), bem como com a dobra cutânea tricipital contralateral abaixo de 14,5mm (p = 0,001). CONCLUSÕES: A freqüência da queixa estética foi de 35,1% na amostra. Pacientes masculinos; submetidos à tenotomia do CLB no lado dominante; com IMC abaixo de 30; com dobra cutânea abdominal abaixo de 23,2mm e dobra cutânea tricipital contralateral abaixo de 14,5mm são considerados de risco para apresentar queixa estética da deformidade residual.<br>OBJECTIVE: To analyze the frequency of esthetic complaints after tenotomy of the long head of the biceps in order to create a criterion for some pre-operative analysis that could identify patients that tend to complain about esthetics after the procedure, and thus reduce the incidence. METHODS: A group of 89 patients (90 shoulders) submitted to arthroscopic tenotomy of the long head of the biceps was analyzed. Patients included in the study had their bodily mass index (BMI) measured and were classified into different degrees of obesity. The abdominal skin fold and the contralateral tricipital skin fold were measured with a millimeter-graded adipometer, and the biotype of each individual was determined by the angle measured in the xiphoid appendix. Tenotomy of the long head of the biceps, when indicated, was performed at its insertion in the upper labrum of the glenoid. Patients were asked about their perception of residual deformity created by the tenotomy of the long head of the biceps. Variables studied were age, gender, operated side, dominance, biotype, degree of obesity, abdominal skin fold, and contralateral tricipital skin fold. 77 patients were evaluated for a mean 15.14 (± 10.7) months period after the surgery. RESULTS: 50 patients (64.9%) did not complain about deformity, whereas 27 patients (35.1%) had some esthetic complaint. Statistical analysis was not significant in the cross analysis for age (P = 0.788), the side (P = 0.075), and the biotype (P = 0.529) of the patients who did present an esthetic complaint about their residual deformity. Significant correlation of deformity complaint was present in the evaluation of gender (p = 0.004), dominance (P = 0.026), and when a group was formed of patients with BMI below 30 (normal and overweight) and this group was compared to patients with BMI above 30 (obesity grade one, two, and morbid) (P = 0.005). A significant correlation was shown for the deformity complaint in patients with abdominal skin fold of less than 23.2 mm (P = 0.003), and with the contralateral tricipital skin fold of less than 14.5 mm (p = 0.001). CONCLUSIONS: The frequency of esthetic complaint was of 35.1% in the series. Male patients; submitted to tenotomy of the long head of the biceps on the dominant side, with BMI below 30; with abdominal skin fold of less than 23.2 mm and contralateral tricipital skin fold of less than 14.5 mm are considered at risk of presenting some esthetic complaint regarding residual deformity

    Complicações da técnica de fixação tibial com parafuso e arruela para a reconstrução ligamentar do joelho Complications of the screw/washer tibial fixation technique for knee ligament reconstruction

    No full text
    OBJETIVO: Avaliar a presença de dor ao nível da ferida operatória e a necessidade de retirada do parafuso de fixação tibial na reconstrução do ligamento cruzado anterior (LCA) do joelho e com o sexo e o índice de massa corporal (IMC). MÉTODOS: Um grupo de 265 pacientes submetidos à reconstrução do LCA com enxerto ipsilateral dos tendões flexores da coxa em que o método de fixação tibial do enxerto foi o parafuso cortical com arruela metálica entre seis de julho de 2000 e 19 de novembro de 2007. RESULTADO: 176 pacientes foram avaliados com uma média de 33,3 ± 19,5 meses (mediana de 29,5 meses) (IIQ: 17-45 meses) - mínima de oito e máxima de 87 meses. Não houve diferença estatística ao analisar a queixa de dor no parafuso (p = 0,272) e a necessidade de retirada do mesmo (p = 0,633) entre os sexos. Não houve diferença estatística ao analisar a queixa de dor no parafuso (p = 0,08) e a necessidade de retirada do mesmo (p = 0,379) ao analisar o IMC. CONCLUSÕES: A utilização do parafuso e arruela metálica para fixação tibial na reconstrução do LCA demonstrou um índice de queixa de dor no sítio do parafuso na ordem de 25% e necessidade de sua retirada em 10,8% dos casos. Não houve predominância de queixas de dor na ferida operatória entre os sexos. Observou-se uma tendência a maior queixa de dor entre indivíduos com IMC OBJECTIVE: To evaluate the presence of pain at the site of the surgical incision and the need to remove the tibial fixation screw after arthroscopic anterior cruciate ligament (ACL) reconstruction in relation to sex and body mass index (BMI). METHODS: A group of 265 patients who underwent ACL reconstruction with ipsilateral flexor tendon grafts from the thigh using a screw and washer as the tibial fixation technique between July 2000 and November 2007 . RESULTS: 176 patients were evaluated for an average of 33.3 ± 19.5 months (median of 29.5 months) (IIQ: 17- 45 months) - minimum of 8 and maximum of 87 months. There was no statistical difference found upon analyzing complaints of pain at the site of the screw (p=0.272) and the need to remove the tibial screw (p=0.633) between sexes. No statistical differences were found concerning complaints of pain at the site of the screw (p=0.08) and the need to remove the tibial screw (p=0.379) according to BMI. CONCLUSION: The screw and metallic washer tibial method used for tibial fixation showed an incidence of pain complaints of 25%, and the need for its removal in 10.8% of the cases. There was no prevalence of complaints of pain at the surgical wound between the sexes. There was a greater tendency to complain about pain among patients with BMI<25. There was no predominance of removal of the screw and washer between the sexes and individuals with different BMIs

    Analgesia para a sutura artroscópica do manguito rotador: estudo comparativo entre o bloqueio interescalênico do plexo braquial e o bloqueio da bursa subacromial contínuo

    No full text
    OBJETIVO: Comparar o nível de dor pós-operatória de pacientes submetidos à sutura artroscópica da lesão do manguito rotador (MR) que receberam protocolos diferentes de analgesia pós-operatória. Demonstrar a relação entre dor e o sexo do paciente, a dimensão da lesão suturada e a utilização da capsulotomia interna. Verificar a prevalência dos efeitos colaterais. MÉTODO: Foram analisados três grupos de pacientes operados entre 1º de junho de 2004 e 31 de maio de 2007. O grupo I foi composto pelos pacientes que receberam bloqueio interescalênico com ropivacaína a 0,75%. No grupo II, o mesmo bloqueio foi acrescido de 150µg de clonidina. No grupo III foi administrado um bolus de 30ml de ropivacaína a 0,75% para infiltração dos portais artroscópicos e diretamente no espaço subacromial, seguido de infusão contínua de ropivacaína a 0,2% em bomba de infusão. Os pacientes foram submetidos à medição da escala analógica visual (EAV) com 24 horas após o procedimento. As variáveis estudadas foram: EAV, sexo, tamanho da lesão, necessidade de capsulotomia interna e prevalência dos efeitos colaterais. O estudo avaliou 196 pacientes, dos quais foram excluídos 51, totalizando n = 145 pacientes. O total de pacientes no grupo I foi de 65; no grupo II, de 19; e no grupo III, de 61. RESULTADOS: O índice da EAV médio encontrado no grupo I foi de 3,88 ± 1,737 (3); no grupo II, de 3,8 ± 1,6 (3); e no grupo III, de 1,95 ± 1,6 (2). Houve diferença significativa ao comparar os grupos I e III (p < 0,001) e ao comparar os grupos II e III (p < 0,001), sugerindo menor dor nos pacientes do grupo III. Não houve diferença para a percepção da dor entre os sexos (p = 0,700) e entre os diferentes tamanhos de lesão do MR (p = 0,546). Houve diferença na percepção da dor entre os pacientes submetidos ou não à capsulotomia interna (p = 0,038). Houve redução na prevalência das náuseas e/ou vômitos (p = 0,089) e do prurido (p = 0,092) no grupo III, quando comparado com os grupos I e II. CONCLUSÕES: O protocolo de analgesia pós-operatória com infusão contínua de ropivacaína demonstrou ser superior aos protocolos que utilizam morfina após o término do efeito do bloqueio interescalênico. Não houve distinção na percepção da dor entre os sexos e diferentes tamanhos de lesões suturadas. Houve distinção na percepção da dor entre os pacientes que realizaram ou não a capsulotomia interna. O índice de efeitos colaterais foi semelhante entre os protocolos de analgesia
    corecore